HPLC Certified

High quality and cost effective syringe filters are
available in a broad range of membrane materials
with sterile and non-sterile packaging options.

Features

  • Disposable
  • Luer-Lok™ and pressure fitting
  • Ultrasonically bonded for reliability
  • Filter media type clearly inscribed on barrel
  • Excellent unit-to-unit and lot-to-lot reproducibility and consistency
  • High purity virgin polypropylene housing, no dyes or pigments added
  • Every unit type is available as an individually wrapped gamma sterilized pack
  • Unique concentric funnel shaped barrel increases volume and decreases back pressure

Product Selection Guide

Evaluate sample:

  • Determine chemical compatibility, volume and need for prefiltration

Determine level of prefiltration necessary:

  • In filter unit vs. prefilter unit in series for coarse precipitants.

Choose filter media type:

  • Aqueous: Nylon, MCE, CA
  • Non-polar: Nylon, PTFE, PVDF
  • Protein: PVDF, PES

Choose barrel diameter:

  • 10 mL: 13 mm diameter
  • 100 mL: 25 mm diameter

Choose initial or secondary retention target:

  • 0.45 µm or 0.20 µm

Download product literature now!

Check out our newest product - HydroBlokr™ serological pipette device filter



 

Filter Material Specs

Filtration Media / Application Guide (hydrophobic or hydrophilic)
Glass microfiber filter media - prefilter versions available in all variations except MultiDensity which includes prefilter

MCE Syringe filterMixed Cellulose Esters (MCE) - Hydrophilic

  • This membrane is recommended for all filtrations in aqueous or polar media, bacteria filtration
  • Ideal when maximum protein recovery in filtrate is crucial
  • Used for filtration and inspection of gas, oil and alcohol particulate and bacteria
  • Combined with glass microfiber prefilter, ideal for tissue culture media and sensitive biological samples
  • Sample filtration - prefilter increases yield

Cellulose acetate (CA) - Hydrophilic

  • Very low binding capacity for proteins.
  • Material is nitrate-free making it suitable for groundwater & EPA ASTM’s.
  • For filtration under sterile conditions
  • Filtration and clarification of biological fluids, sterilization of media additives and serum
  • Sample preparation of aqueous solutions
  • For applications requiring maximum sample recovery
  • Sample preparation of protein-based HPLC solutions
  • Designed to sterilize and remove particulates from even the most viscous proteinaceous samples
  • Filtration of tissues culture media with glass fiber prefilter

Polyamide/Nylon (PA) - Hydrophilic

  • Hydrophilic material; it is recommended for filtration of aqueous or organic/aqueous medium polar liquids.
  • Commonly used for general laboratory filtration and filtration of HPLC and GC samples prior to injection
  • Filtration of aqueous and organic-aqueous polar medium liquids
  • Dissolution sample analysis
  • Suitable for use with high pH samples
  • Since it binds proteins it is NOT suitable for protein recovery applications
  • With microfiber prefilter higher absorption capacity for contamination

Polyethersulfone (PES) - Hydrophilic

  • High filtration flow rates
  • An inherently low affinity for proteins.
  • Low extractables
  • Introduction of additives into tissue culture vessel.
  • Certified for Ion Chromatography
  • Final filtration of bacteriophage and infusion solutions
  • Tissue culture, proteins, buffer and nucleic acids filtration
  • Ideal for applications requiring maximum sample recovery
  • Filter hybridization solutions and probe to reduce backgrounds
  • Food, beverages and ultra pure water final filtration
  • Sterile product individually blister packed

Polyvinylidene difluoride (PVDF) - Hydrophobic

  • This membrane features a stability and hydrophobic interactions similar to PTFE.
  • Recommended especially for filtration of water-soluble oligomers and polymers, e.g. protein solutions.
  • Can also be used for the filtration of hydrophobic substances in different organic solvents.

Polytetrafluoroethylene (PTFE) - Hydrophilic or Hydrophobic

  • PTFE membranes are inherently hydrophobic; they are ideal for the filtration of nonpolar liquids and gases.
  • Very resistant to solvents as well as acids or bases.
  • Can be made more hydrophilic by flushing with alcohol, followed by water
  • Used for filtering and de-gassing chromatography solvents
  • Permits optimal utilization of small sample volumes
  • Excellent chemical compatibility for filtering harsh chemicals that destroy other membrane materials
  • Moisture barrier for venting applications and vacuum pump line protection
  • Ideal for aerosol sampling
  • Filter viscous organic based HPLC samples
  • After pre-wetting with alcohol, may be used for fine particle removal of aqueous and mild organic solutions in Ion Chromatography

Glass Fiber Prefilters

  • For viscose solutions or for turbid liquids
  • Glass microfiber prefilter raises absorption capacity and loading
  • Ideal for use as a prefilter in series with other syringe filters
  • Glass microfiber filter media enclosed in this series is binderless 1.0µm retention
  • Reduces clogging of the membrane, so ideal as a prefilter to increase throughput and flow rate
  • Ideal for dissolution testing and general filtration
  • Applicable to all membrane types, allowing higher flow rates
  • Good compatibility with strong acids, bases and organic solvents
  • Similar in composition to I.W. Tremont binderless borosilicate glass microfiber media available as disks and sheets

Polypropylene (PP)

  • The polypropylene membrane is resistant to many organic solvents and slightly hydrophobic
  •  Useful for aqueous and organic solutions
  • Low non-specific protein binding

MultiDensity Nano Glass Micro Fiber 

  • Multi Density Glass Microfiber with several layers of density that speeds and optimizes filtration
  • Bridges the gap between macro and micro analytical filtration
  • Media includes multi pre-filtration stages and final retention stage down to 0.5um
  • Built-in prefilter captures particulate from >300μm and binds typically difficult to filter substances without clogging such as lipids (natural oils and waxes), petrochemical oils, tars, cellular matter and proteins.

Nano Glass Micro Fiber A83

  • Nano-scale glass microfiber has the loading capacity of a binderless glass microfiber filter with the tightly regulated pore size of a microfiltration membrane
  • This specialty grade has a particle retention of 0.5µm
  • A83 has >20x loading capacity of an equivalent porosity MCE or CN membrane and >15x the flow rate
  • Chemically inert, pure binderless borosilicate glass with no sizing additives or other surfactants
  • Low background noise in LC/GC/MS and very low extractables in presence of aggressive solvents
  • Smooth sheath of the glass fiber allows tight consolidation into a highly retentive filter mat
  • High protein affinity and highly washable for separation recovery
  • Chemically stable in presence of all acids with exception of hydrofluoric acid

Fibrous Cellulose Acetate

  • Fibrous Cellulose Acetate depth filter media demonstrates a high surface area to mass ratio and natural high loading capacity
  • Unique fibrous material demonstrates similar advantages as its Cellulose Acetate surface membrane counterparts such as surface bonding, high purity and biocompatibility
  • Fibrous media has an inherent charge that initially has high protein binding but upon loading, releases easily and completely for high recovery rates

Tri-Layer PP/GF Prefilters with Nylon, PVDF or PTFE Membrane

  • A tri-layer filter with both a glass microfiber and polypropylene prefilter that raises absorption capacity and loading of a choice of Nylon PTFE or PVDF membrane
  • Designed for viscous solutions or for turbid liquids

Technical Specifications:
Typical physical characteristics:
  13mm diameter barrel 25mm diameter barrel
     
Surface area (cm²) 0.65 3.90
Sample volume (ml) <15 <105
Maximum pressure (bar) 45 90
Hold up volume (µl) 8.5 28.5
Connector inlet Luer-Lok™ Luer-Lok™
Connector outlet luer-slip (non-barb) luer-slip (non-barb)
 

Syringe Filters Products

Material Classifications>

Polyamide/Nylon (PA) – Hydrophilic

Polytetrafluoroethylene (PTFE) – Hydrophilic or Hydrophobic

Polyvinylidene difluoride (PVDF) – Hydrophobic

Polyethersulfone (PES) – Hydrophilic

Cellulose Acetate (CA) – Hydrophilic

Mixed Cellulose Esters (MCE)-Hydrophilic

Prefilters, Glass Microfiber

Polypropylene (PP)

MultiDensity Nano Glass Microfiber

Nano Microfiber

Cellulose Acetate Fibrous

Tri-Layer PP/GF with  Nylon, PVDF, PTFE

Product Catalog # Description
IWT-ES10000 Nonsterile Nylon Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10001 Nonsterile Nylon Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10002 Nonsterile Nylon Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10003 Nonsterile Nylon Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10004 Nonsterile Nylon Syringe Filters, 0.22(μm), 33(mm), 100 pack
IWT-ES10005 Nonsterile Nylon Syringe Filters, 0.45(μm), 33(mm), 100 pack
IWT-ES10007 Sterile Nylon Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10008 Sterile Nylon Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10009 Sterile Nylon Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10010 Sterile Nylon Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10011 Sterile Nylon Syringe Filters, 0.22(μm), 33(mm), 100 pack
IWT-ES10012 Sterile Nylon Syringe Filters, 0.45(μm), 33(mm), 100 pack
IWT-ES10180 Nonsterile Nylon Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10181 Nonsterile Nylon Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10182 Nonsterile Nylon Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10183 Nonsterile Nylon Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10185 Sterile Nylon Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10186 Sterile Nylon Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10187 Sterile Nylon Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10188 Sterile Nylon Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10232 Nonsterile Nylon Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10233 Nonsterile Nylon Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10234 Nonsterile Nylon Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10235 Nonsterile Nylon Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10237 Sterile Nylon Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10238 Sterile Nylon Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10239 Sterile Nylon Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10240 Sterile Nylon Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10300 Nonsterile Nylon Syringe Filters, 0.22 (µm), 17 (mm), 100 pack
IWT-ES10301 Nonsterile Nylon Syringe Filters, 0.45 (µm), 17 (mm), 100 pack
IWT-ES10302 Nonsterile Nylon Syringe Filters, 0.22 (µm), 30 (mm), 100 pack
IWT-ES10303 Nonsterile Nylon Syringe Filters, 0.45 (µm), 30 (mm), 100 pack
IWT-ES10304 Sterile Nylon Syringe Filters, 0.22 (µm), 30 (mm), 100 pack
IWT-ES-10601 Nonsterile Nylon syringe filter, 4mm diameter, 0.22(µm), membrane, 200pk
IWT-ES-10602 Nonsterile Nylon syringe filter, 4mm diameter, 0.45(µm), membrane, 200pk
Back To Top
IWT-ES10017 Nonsterile PTFE Syringe Filters, 0.22(μm), 13(mm), Hydrophobic, 100 pack
IWT-ES10018 Nonsterile PTFE Syringe Filters, 0.45(μm), 13(mm), Hydrophobic, 100 pack
IWT-ES10019 Nonsterile PTFE Syringe Filters, 0.22(μm), 25(mm), Hydrophobic, 100 pack
IWT-ES10020 Nonsterile PTFE Syringe Filters, 0.45(μm), 25(mm), Hydrophobic, 100 pack
IWT-ES10024 Sterile PTFE Syringe Filters, 0.22(μm), 13(mm), Hydrophobic, 100 pack
IWT-ES10025 Sterile PTFE Syringe Filters, 0.45(μm), 13(mm), Hydrophobic, 100 pack
IWT-ES10026 Sterile PTFE Syringe Filters, 0.22(μm), 25(mm), Hydrophobic, 100 pack
IWT-ES10027 Sterile PTFE Syringe Filters, 0.45(μm), 25(mm), Hydrophobic, 100 pack
IWT-ES10603 Nonsterile PTFE syringe filter,  0.22(μm), 4(mm) ,Hydrophobic, 200pk
IWT-ES10604 Nonsterile PTFE syringe filter,  0.45(μm), 4(mm) ,Hydrophobic, 200pk
IWT-ES10034 Nonsterile PTFE Syringe Filters, 0.22(μm), 13(mm), Hydrophilic, 100 pack
IWT-ES10035 Nonsterile PTFE Syringe Filters, 0.45(μm), 13(mm), Hydrophilic, 100 pack
IWT-ES10036 Nonsterile PTFE Syringe Filters, 0.22(μm), 25(mm), Hydrophilic, 100 pack
IWT-ES10037 Nonsterile PTFE Syringe Filters, 0.45(μm), 25(mm), Hydrophilic, 100 pack
IWT-ES10039 Sterile PTFE Syringe Filters, 0.22(μm), 13(mm), Hydrophilic, 100 pack
IWT-ES10040 Sterile PTFE Syringe Filters, 0.45(μm), 13(mm), Hydrophilic, 100 pack
IWT-ES10041 Sterile PTFE Syringe Filters, 0.22(μm), 25(mm), Hydrophilic, 100 pack
IWT-ES10042 Sterile PTFE Syringe Filters, 0.45(μm), 25(mm), Hydrophilic, 100 pack
IWT-ES10605 Nonsterile PTFE syringe filter,  0.22(μm), 4(mm) ,Hydrophilic, 200pk
IWT-ES10606 Nonsterile PTFE syringe filter,  0.45(μm), 4(mm) ,Hydrophilic, 200pk
IWT-ES10141 Nonsterile PTFE Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10142 Nonsterile PTFE Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10143 Nonsterile PTFE Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10144 Nonsterile PTFE Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10146 Sterile PTFE Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10147 Sterile PTFE Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10148 Sterile PTFE Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10149 Sterile PTFE Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10193 Nonsterile PTFE Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10194 Nonsterile PTFE Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10195 Nonsterile PTFE Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10196 Nonsterile PTFE Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10198 Sterile PTFE Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10199 Sterile PTFE Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10200 Sterile PTFE Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10201 Sterile PTFE Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10320 Nonsterile PTFE Syringe Filters, 0.22 (µm), 17 (mm), 100 pack
IWT-ES10321 Nonsterile PTFE Syringe Filters, 0.45 (µm), 17 (mm), 100 pack
IWT-ES10322 Nonsterile PTFE Syringe Filters, 0.22 (µm), 30 (mm), 100 pack
IWT-ES10323 Nonsterile PTFE Syringe Filters, 0.45 (µm), 30 (mm), 100 pack
Back To Top
IWT-ES10047 Nonsterile PVDF Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10048 Nonsterile PVDF Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10049 Nonsterile PVDF Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10050 Nonsterile PVDF Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10054 Sterile PVDF Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10055 Sterile PVDF Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10056 Sterile PVDF Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10057 Sterile PVDF Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10167 Nonsterile PVDF Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10168 Nonsterile PVDF Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10169 Nonsterile PVDF Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10170 Nonsterile PVDF Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10172 Sterile PVDF Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10173 Sterile PVDF Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10174 Sterile PVDF Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10175 Sterile PVDF Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10219 Nonsterile PVDF Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10220 Nonsterile PVDF Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10221 Nonsterile PVDF Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10222 Nonsterile PVDF Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10224 Sterile PVDF Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10225 Sterile PVDF Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10226 Sterile PVDF Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10227 Sterile PVDF Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10330 Nonsterile PVDF Syringe Filters, 0.22 (µm), 17 (mm), 100 pack
IWT-ES10331 Nonsterile PVDF Syringe Filters, 0.45 (µm), 17 (mm), 100 pack
IWT-ES10332 Nonsterile PVDF Syringe Filters, 0.22 (µm), 30 (mm), 100 pack
IWT-ES10333 Nonsterile PVDF Syringe Filters, 0.45 (µm), 30 (mm), 100 pack
IWT-ES-10607 Nonsterile PVDF Syringe Filters syringe filter,0.22(µm), 4 (mm) , 200PK
IWT-ES-10608 Nonsterile PVDF Syringe Filters, syringe filter,, 0.45(µm), 4 (mm) , 200PK
Back To Top
IWT-ES10064 Nonsterile PES Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10065 Nonsterile PES Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10066 Nonsterile PES Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10067 Nonsterile PES Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10071 Sterile PES Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10072 Sterile PES Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10073 Sterile PES Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10074 Sterile PES Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10154 Nonsterile PES Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10155 Nonsterile PES Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10156 Nonsterile PES Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10157 Nonsterile PES Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10159 Sterile PES Syringe Filters, 0.22(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10160 Sterile PES Syringe Filters, 0.45(μm), 13(mm), PP prefilter, 100 pack
IWT-ES10161 Sterile PES Syringe Filters, 0.22(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10162 Sterile PES Syringe Filters, 0.45(μm), 25(mm), PP prefilter, 100 pack
IWT-ES10206 Nonsterile PES Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10207 Nonsterile PES Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10208 Nonsterile PES Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10209 Nonsterile PES Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10211 Sterile PES Syringe Filters, 0.22(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10212 Sterile PES Syringe Filters, 0.45(μm), 13(mm), GF prefilter, 100 pack
IWT-ES10213 Sterile PES Syringe Filters, 0.22(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10214 Sterile PES Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack
IWT-ES10310 Nonsterile PES Syringe Filters, 0.22 (µm), 17 (mm), 100 pack
IWT-ES10311 Nonsterile PES Syringe Filters, 0.45 (µm), 17 (mm), 100 pack
IWT-ES10312 Nonsterile PES Syringe Filters, 0.22 (µm), 30 (mm), 100 pack
IWT-ES10313 Nonsterile PES Syringe Filters, 0.45 (µm), 30 (mm), 100 pack
IWT-ES10609 Nonsterile PES syringe filter,0.22(µm), 4 (mm), membrane, 200PK
IWT-ES10610 Nonsterile PES syringe filter, 0.45(µm),4 (mm),   membrane, 200PK
Back To Top
IWT-ES10081 Nonsterile CA Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10082 Nonsterile CA Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10083 Nonsterile CA Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10084 Nonsterile CA Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10088 Sterile CA Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10089 Sterile CA Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10090 Sterile CA Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10091 Sterile CA Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10611 Nonsterile CA syringe filter, 4mm diameter, 0.22micron, membrane, 200PK
IWT-ES10612 Nonsterile CA syringe filter, 4mm diameter, 0.45micron, membrane, 200PK
Back To Top
IWT-ES10098 Nonsterile MCE Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10099 Nonsterile MCE Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10100 Nonsterile MCE Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10101 Nonsterile MCE Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10105 Sterile MCE Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10106 Sterile MCE Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10107 Sterile MCE Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10108 Sterile MCE Syringe Filters, 0.45(μm), 25(mm), 100 pack
Back To Top
IWT-ES10115 Nonsterile GF Syringe Filters, 0.70(μm), 13(mm), 100 pack
IWT-ES10116 Nonsterile GF Syringe Filters, 1.00(μm), 13(mm), 100 pack
IWT-ES10117 Nonsterile GF Syringe Filters, 0.70(μm), 25(mm), 100 pack
IWT-ES10118 Nonsterile GF Syringe Filters, 1.00(μm), 25(mm), 100 pack
IWT-ES10120 Sterile GF Syringe Filters, 0.70(μm), 13(mm), 100 pack
IWT-ES10121 Sterile GF Syringe Filters, 1.00(μm), 13(mm), 100 pack
IWT-ES10122 Sterile GF Syringe Filters, 0.70(μm), 25(mm), 100 pack
IWT-ES10123 Sterile GF Syringe Filters, 1.00(μm), 25(mm), 100 pack
Back To Top
IWT-ES10128 Nonsterile PP Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10129 Nonsterile PP Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10130 Nonsterile PP Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10131 Nonsterile PP Syringe Filters, 0.45(μm), 25(mm), 100 pack
IWT-ES10133 Sterile PP Syringe Filters, 0.22(μm), 13(mm), 100 pack
IWT-ES10134 Sterile PP Syringe Filters, 0.45(μm), 13(mm), 100 pack
IWT-ES10135 Sterile PP Syringe Filters, 0.22(μm), 25(mm), 100 pack
IWT-ES10136 Sterile PP Syringe Filters, 0.45(μm), 25(mm), 100 pack
Back To Top
IWT-ES-10701 Nonsterile MultiDensity Syringe Filters, 0.5(μm), 25(mm), 100 pack
IWT-ES-10702 Nonsterile MultiDensity Syringe Filters, 0.7(μm), 25(mm), 100 pack
IWT-ES-10703 Nonsterile MultiDensity Syringe Filters, 1.0(μm), 25(mm), 100 pack
IWT-ES-10704 Nonsterile MultiDensity Syringe Filters, 1.2(μm), 25(mm), 100 pack
IWT-ES-10705 Nonsterile MultiDensity Syringe Filters,1.5(μm), 25(mm), 100 pack
IWT-ES-10706 Nonsterile MultiDensity Syringe Filters, 1.6(μm), 25(mm), 100 pack
IWT-ES-10707 Nonsterile MultiDensity Syringe Filters, 2.7(μm), 25(mm), 100 pack
Back To Top
IWT-ES-10801 Nonsterile A83 NanoScale Syringe Filters, 0.5(μm), 15(mm), 100 pack
IWT-ES-10802 Nonsterile A83 NanoScale Syringe Filters, 0.5(μm), 25(mm), 100 pack
IWT-ES-10803 Nonsterile A83 NanoScale Syringe Filters, 0.5(μm), 30(mm), 100 pack
Back To Top
IWT-ES-10751 High purity CA fibrous protein Syringe Filters, hydrophilic,  1.0(μm), 15(mm), 100 pack
IWT-ES-10752 High purity CA fibrous protein Syringe Filters, hydrophilic,  1.0(μm), 25(mm), 100 pack
Back To Top
IWT-ES10400 Tri-Layer PP/GF prefilter Nonsterile Nylon Syringe Filters, 0.45(µm),25(mm),100 /pack
IWT-ES10401 Tri-Layer PP/GF prefilter Nonsterile Nylon Syringe Filters, 0.22(µm), 25(mm),100 /pack
IWT-ES10405 Tri-Layer PP/GF prefilter Nonsterile PVDF Syringe Filters, 0.45(µm),25(mm),100 /pack
IWT-ES10406 Tri-Layer PP/GF prefilter Nonsterile PVDF Syringe Filters, 0.22(µm), 25(mm),100 /pack
IWT-ES10410 Tri-Layer PP/GF prefilter Nonsterile PTFE Syringe Filters, 0.45(µm),25(mm),100 /pack, hydrophobic
IWT-ES10411 Tri-Layer PP/GF prefilter Nonsterile PTFE SyringeFilters, 0.22(µm), 25(mm),100 /pack, hydrophobic

 

Syringe Filter Capabilities

Beyond the extensive product selection found within our standard syringe filter list, we offer OEM capabilities for engineering, molding and insertion of many additional membrane and membrane/pre-filter options.   We can work with most of our own membrane and specialty materials as well as convert your supplied product.  Please contact us for full engineering capabilities as well as process flow and project management services in this field.

  • Filter insertion in clean room by manual as well as fully automated means.
  • Molding in place, over molding and support structure molding of fragile media.
  • Ultrasonic welding of barrel structure for increased leak / burst resistance.
  • Multi-process mold extensions for inclusion of single or multi-level prefiltration media.
  • Digital variable print capabilities along arc on barrel face for identification purposes.
  • Blister packing for EO and gamma sterilization.
  • Pure virgin PP, verified by HPLC against U/L extractables.

13mm diameter syringe filter:

  • Filter Ø: 13 mm
  • Filtration area: 1.09 mm2
  • Housing material: polypropylene
  • Holdup volume: <20 µl
  • Sample volume: <10 ml
  • Maximum Operating Temperature: 130°C (Housing only, also dependent on membrane)
  • Maximum Operating Pressure: 87 psi (Housing only, also dependent on membrane)
  • Inlet: Luer lock female
  • Outlet: Luer slip male

17mm diameter syringe filter:

  • Filter Ø: 17 mm
  • Filtration area: 1.65 cm2
  • Housing material: polypropylene
  • Holdup volume: <20 µl
  • Sample volume: <20 ml
  • Max. housing pressure: 8 bar
  • Maximum Operating Temperature: 80°C (Housing only, also dependent on membrane)
  • Maximum Operating Pressure: 87 psi (Housing only, also dependent on membrane)
  • Inlet: Luer lock female
  • Outlet: Luer slip male
  • Biological Safety: Filter medium and housing material meet USP XXII Class VI,121 ℃

25mm diameter syringe filter:

  • Filter Ø: 25 mm
  • Filtration area: 4.08 cm2
  • Housing material: polypropylene
  • Holdup volume: <100 µl
  • Sample volume: <100 ml
  • Maximum Operating Temperature: 130°C (Housing only, also dependent on membrane)
  • Maximum Operating Pressure: 87 psi (Housing only, also dependent on membrane)
  • Inlet: Luer lock female
  • Outlet: Luer slip male
  • Biological Safety: Filter medium and housing material meet USP XXII Class VI,121 ℃

30mm diameter syringe filter:

  • Filtration area: 4.9cm2
  • Housing material: polypropylene
  • Holdup volume: <100 µl
  • Sample volume: <120 ml
  • Max. housing pressure: 8 bar
  • Maximum Operating Temperature: 80°C (Housing only, also dependent on membrane)
  • Maximum Operating Pressure: 87 psi (Housing only, also dependent on membrane)
  • Inlet: Luer lock female
  • Outlet: Luer slip male
  • Biological Safety: Filter medium and housing material meet USP XXII Class VI,121 ℃

50mm diameter in-line filter:

  • Housing Polypropylene
  • Connector Inlet/Outlet: 7~13 mm stepped hose barb connection
  • Filtration Area, ft² ≥0.021
  • Maximum Operating Pressure Forward: 3.5 bar @ 23℃ and 3.0 bar @ 60℃ for liquid, 3.0 bar @ 23℃ and 2.5 bar @ 60℃ for air & gas
  • Sterilization By EO, gamma or autoclave cycle of 30 min at 123℃; steam-in-place sterilization not recommended


© 2023 1-IW Tremont - All Rights Reserved - SG


Back to top