Row filter-holdings-swoopty Shape Decorative svg added to bottom <

Diagnostics Materials

A complete line of lateral and vertical flow diagnostic materials with the efficacy of complete device in minds

Row filter-holdings-swoopty Shape Decorative svg added to bottom <
Precision-Engineered Media for Rapid and Reliable Results

Diagnostic Device Materials

I.W. Tremont delivers a comprehensive suite of diagnostic-grade materials tailored for lateral-flow and vertical-flow applications: 

  • High yield whole blood separators
  • Dried Blood Spot paper
  • Absorbent pad
  • Conjugate pad
  • Wicking materials
  • Membranes
  • High resolution indicator paper
  • Base plane
  • Absorbent sinks

Designed for consistent performance—from high-yield plasma separation with no red-cell hemolysis to high-resolution indicator paper and high-capacity fluidic wells—these components enable critical diagnostics across point-of-care, laboratory and OEM devices

checking glucose level

D-23® Plasma Separator demo in a simple microfluidic device concept

D-23® surface
wetting demonstration

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

Diagnostics Material Specs


Grade NomenclatureNameFunctionDescriptionThickness (mm)Retention (μm)Basis Weight (g/m2)
D-23®Whole Blood Separation Media

High efficacy and high quality plasma separator with  no red cell hemolysis

Borosillicate glass media 0.5mm thick, ready for application of your speicalized chemistries, plasma yield >15% by volume0.5494
D23®-TC1Whole Blood Separation Media, Thin CaliperHigh efficacy and high quality plasma separator with  no red cell hemolysis, thin caliper has less holdup volumeBorosillicate glass media with thin caliper, 0.375mm thick, ready for application of your speicalized chemistries, plasma yield >15% by volume0.3753.670
LF-D23®-X1Whole Blood Separation Media. Lateral Flow, Nominal Hct RangeLateral flow plasma separator with  no red cell hemolysisBorosillicate glass media with lateral flow agglutinating chemistry, 0.5mm thick, plasma yield >40% by volume, nominal Hct0.5
LF-D23®-X2Whole Blood Separation Media. Lateral Flow, High Hct Range.Lateral flow plasma separator with  no red cell hemolysisBorosillicate glass media with lateral flow agglutinating chemistry, 0.5mm thick, plasma yield >40% by volume, high Hct0.5
LF-D23®-TC1-X1Whole Blood Separation Media. Lateral Flow, Nominal Hct Range. Thin CaliperLateral flow plasma separator with  no red cell hemolysis and less holdup volumeBorosillicate glass media with lateral flow agglutinating chemistry, thin caliper, 0.375mm thick, plasma yield >40% by volume, nominal Hct0.375
LF-D23®-TC1-X2Whole Blood Separation Media. Lateral Flow, HighHct Range. Thin CaliperLateral flow plasma separator with  no red cell hemolysis and less holdup volumeBorosillicate glass media with lateral flow agglutinating chemistry, thin caliper, 0.375mm thick, plasma yield >40% by volume, high Hct0.375
CF-D23®-X1Whole Blood Separation Media. Cross Flow, Nominal Hct RangeCross flow plasma separator with  no red cell hemolysisBorosillicate glass media with cross flow agglutinating chemistry, 0.5mm thick, plasma yield >40% by volume, nominal Hct0.5
CF-D23®-TC1-X1Whole Blood Separation Media. Cross Flow, Nominal Hct Range. Thin CaliperCross flow plasma separator with  no red cell hemolysis and less holdup volumeBorosillicate glass media with cross flow agglutinating chemistry, thin caliper, 0.375mm thick, plasma yield >40% by volume, nominal Hct0.375
CA-1Cellulose Acetate Fibrous MaterialFluid well, prefilter, absorbent pad, cell scaffold, wick, collection mediaNon-woven material product platform which is highly modifiable in basis weight, density, porosity, surface treatments and other physical attributes
CFP-DBS-v1Dried Blood Spot MediaSpecimen collectionHigh Purity cotton linter microfiber for specimen collection0.44 - 0.47n/a180
WT-2500hpcHigh Purity CelluloseSpecimen collection and indicator paperHigh Purity cotton linter microfiber for specimen collection0.192580
CFP1Collection PadWicking, absorbent conjugate pad, high resolutionHigh Purity cotton linter microfiber for quantitative analysis0.178101
CFP2Collection PadWicking, absorbent conjugate pad, high resolutionHigh Purity cotton linter microfiber for quantitative analysis0.21186
CFP4Collection PadWicking, absorbent conjugate pad, high resolutionHigh Purity cotton linter microfiber for quantitative analysis0.2102594
CFP1654Collection PadWicking, absorbent conjugate pad, high resolutionHigh Purity cotton linter microfiber for quantitative analysis0.7270
WTCFP-PE1Moisture SinkAbsorbent pad, sample wick, impermeable baseHigh Absorbency cotton and soft wood microfiber 0.22140
Grade BCollection PadWicking absorbent conjugate padBinderless Borosilicate Glass Microfiber0.651.0140
Grade CCollection PadWicking absorbent conjugate padBinderless Borosilicate Glass Microfiber0.281.2050
Grade FWicking MaterialSample  collection and wicking pad

Binderless Borosilicate Glass Microfiber

0.400.780
B-85
Glass Microfiber
Wicking absorbent conjugate pad

Binderless Borosilicate Glass Microfiber

0.431.064
RGLaminated Glass MicrofiberWicking absorbent pad

Laminated Borosilicate Glass Microfiber

0.381 - 288.1
LL-72Laminated Glass MicrofiberSample  collection and wicking pad

Double Laminated Borosilicate Glass Microfiber

0.431 - 2115.9
PP1Polypropylene Media

Polypropylene fibrous dept filter

0.681 - 1.2570

Diagnostic Device Materials Guide

Porous Cellulose Papers - Glass Microfiber Media - Membrane

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

I.W. Tremont Diagnostics Products

MATERIAL CLASS:
High Purity Cellulose Acetate

Fibrous Cellulose Acetate

Grade Nomenclature Surface Material Type Thickness
(mm)
Retention
(µm)
Basis Weight
(g/m2)
CA-1Fibrous
Bright White
High purity CA fibers,
no binder
1.45100155.0

Grade CA-1 is a non-woven material product platform which is highly modifiable in basis weight, density, porosity, surface treatments and other physical attributes.

Ideally suited as a

  • Bio-sample collection media
  • Wound care absorbent pad
  • Transdermal drug delivery media
  • Base material in a functionalized separation filter
  • Stand alone, chemical resistant, high loading filter
  • 3D cell scaffold in bioreactors or stirred cell devices
  • Component in bio-sensors
  • Lateral flow absorbent wick
  • High capacity fluidic well for POCT requiring chase buffers
  • Prefilter for higher retention CA surface membrane
  • Respiration & O2 therapy concentrator devices

This unique material demonstrates high surface area to mass ratio and high porosity. It is a fibrous format which differentiates this material from traditional cast films and surface membranes.

Consistent with other forms of Cellulose Acetate (CA) this media is ideal for Biomedical, Pharmaceutical and Life Sciences applications via high purity, good thermal stability, biocompatibility and functionalization.

The media is ideal as a diagnostic device component, wound care dressing, in DNA/RNA separation and amplification techniques and cell recovery.

Grade CA-1
20x magnification, backlit surface view

In cast sheet membrane form, CA is typically low protein binding, making it ideal for high recovery demand applications. This media in fibrous form has an inherent charge making the media initially high protein binding, but upon loading releases easily and completely to yield very high recovery rates. This unique characteristic of the fibrous form of this material is partially due to the electrostatic properties remnant from the spinning technique as well as a proprietary method used to form the fiber as a structurally consistent matrix.

SEM image
SEM image indicates highly uniform fiber structure
fiber geometry
The complex fiber geometry increases surface area

This fibrous material in depth filter form demonstrates similar advantages of its CA surface membrane counterparts such as surface bonding, high purity and biocompatibility. Due to the torturous matrix within the depth of the media, combined with the complex fiber geometry there is a high surface area ratio that can be functionalized using chemical techniques for bonding. The media is also hydrophilic by filling of the void space within the matrix once wetting has begun. With a wetting factor roughly twice that of comparable polymeric fibrous media, this CA media will absorb and release at consistent rates.

The acetate ester of cellulose, which is a abundant natural material derived from the cellular structure of green plants is a widely accepted medical device biopolymer. This makes this media cost efficient and its high demand affords ample commercial supply. The material is compatible with gamma, e-beam and EtO methods of sterilization without degradation.

This grade demonstrates a unique ability to heat set into a caliper thickness without significant deviations in air/gas flow rates which allow device design variations using same base grade.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:
Whole blood separation - Coated agglutinating chemistry

Grade LF-D-23®
Grade CF-D-23®

Coated Whole Blood Separation Media.

Now Available in 2 thicknesses to improve device optimization

Grade D-23® is a high rate, high plasma yield blood separator for both lateral flow and vertical flow immunoassays. This media performs efficiently at a broad range of whole blood sample volumes, including <100µL which further expands your device design capabilities.

Material originates as our D-23® base glass borosilicate glass microfiber filter media containing a proprietary acrylic binder system. The base glass material, although an effective whole blood separator alone, is then treated with a novel coating technology which yields high quality plasma with surprising efficacy, speed and with little-to-no red cell hemolysis. Now available in 2 thicknesses for further optimization of your device design.

Plasma yield of >40%, at a rate of 30-120 seconds is achieved via the agglutinating chemistry and coating technology developed by a CRO in the United States whose specialty is blood separation and device development. This market proven media is currently included as a component in successfully commercialized and patented devices with 510K filings.

The agglutinating coating can be altered to best fit the application, separation rate and whole blood sample size for your device design.

Shown here are 4 titrations of the agglutinating chemistry (using no buffer) illustrating the plasma yield for similar Hct samples by volume and time in a simple lateral flow design.

Plasma yield zone
Resultat plasma yield zone
Blood

Material demonstrates high uniformity in formation and density allowing reliable migration rates, in both cross and lateral flow applications. With little caliper deviation the media is ideal for challenging lamination applications and micro fluidic devices.

Uniform density and stability is ideal for automated device assembly. This media demonstrates excellent lot-to-lot reproducibility - CofC and CofA provided with shipments – Manufactured in an FDA approved facility and available as rolls, reels, sheets and semi-finished converted configurations in both pre and post coated versions.

This media is also available as a base glass microfiber which performs basic whole blood separation via precisely engineered porosity and fiber matrix. In the natural uncoated configuration both caliper versions intrinsically demonstrate plasma yield of approximately 15% by volume at nominal Hct range. It is suitable for both lateral and vertical flow configurations and is highly consistent in density and caliper for application of your own micro-coating and dip/dry saturation chemistry.

3 plasma separation modes in 2 material thicknesses are now available containing proprietary agglutinating chemistry coating. In this coated versions demonstrate plasma yield >40%.

  • Coated for high yield agglutinating process, LATERAL FLOW
    Hct RANGE: NOMINAL = x1
    Hct RANGE: HIGH = x2
  • Coated for high yield agglutinating process, CROSS FLOW (vertical)
    Hct Range: NOMINAL = x1

Basic material physical characteristics:

Basis Weight
(g/m2)
Caliper Thickness
(mm)
Micron Retention
(µm)
Tensile strength
(lb)
Basic migration rate
D-23®
94.40.503-58.0 MD, 4.0 CD35 sec. / 4cm
D23®-TC1
70.00.3753.67.0 MD, 5.5 CD28 sec. / 4cm

Known competitive grades*:

  • GE Healthcare Whatman Fusion 5
  • GE Healthcare Whatman GF/DVA, LF1, MF & VF2
  • Ahlstrom / Pall Cytosep®
sample kit for coated D-23® variants

Please request your device developer’s sample kit for coated D-23® variants along with additional technical information.

Coated with high yield agglutinating process chemistry,
LATERAL FLOW

  • LF-D23-X1 (thick version, designed for nominal Hct range, lateral flow)
  • LF-D23-X2 (thick version, designed for high Hct range, lateral flow)
  • LF-D23-TC1-X1 (thin version, designed for nominal Hct range, lateral flow)
  • LF-D23-TC1-X2 (thin version, designed for high Hct range, lateral flow)

 

Coated with high yield agglutinating process chemistry,
CROSS FLOW

  • CF-D23-X1 (thick version, designed for nominal Hct range, cross flow vertical applications)
  • CF-D23-TC1-X1 (thin version, designed for nominal Hct range, cross flow vertical applications)
Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:

Cellulose Acetate Fibrous Material

Grade CA-1 is a non-woven material product platform which is highly modifiable in basis weight, density, porosity, surface treatments and other physical attributes. This unique material demonstrates high surface area to mass ratio and high porosity. It is a fibrous format which differentiates this material from traditional cast films and surface membranes. Consistent with other forms of Cellulose Acetate (CA) this media is ideal for Biomedical, Pharmaceutical and Life Sciences applications via high purity, good thermal stability, biocompatibility and functionalization.

Ideally suited as

  • Bio-sample collection media
  • Wound care absorbent pad
  • Transdermal drug delivery media
  • Base material in a functionalized separation filter
  • Stand alone, chemical resistant, high loading filter
  • 3D cell scaffold in bioreactors or stirred cell devices
  • Component in bio-sensors
  • Lateral flow absorbent wick
  • High capacity fluidic well for POCT requiring chase buffers
  • Prefilter for higher retention CA surface membrane
  • Respiration & O2 therapy concentrator devices
Environmental Sciences
Row filter-holdings-swoopty Shape Decorative svg added to bottom <

Dried Blood Spot Analysis

Grade CFP-DBS-v1

Nomenclature Surface Material Type Thickness
(mm)
Migration Basic weight
(g/m2)
CFP-DBS-v1Very Smooth
Bright White
Cotton Linter Cellulose
Paper
0.44 – 0.47120 - 135180

High purity alpha cotton linter absorbent filter paper specifically formulated to yield a stable DNA, RNA and protein biomarker matrix for quantitative analysis. Surface texture, absorption rate and formation have been optimized for the Guthrie test. The formation is highly uniform and free from density irregularities.

The purity, formation, basis weight and caliper of this material offers a highly reproducible platform for direct elution techniques. Meets or exceeds results obtained using conventional manual extraction methodology in comparison to known competitive commercial equivalents. Paper punches cleanly demonstrating minimal extraneous fibers. Material holds embossing with or without heat set and converts well for incorporation into diagnostic devices.

Uniform screen & felt sides with consistent density MD/CD - Manufacturing performed with RO water filtration system - This media demonstrates excellent lot-to-lot reproducibility - Material
chemistries are verified against a standard using GC techniques prior to paper making process - CofC and CofA provided with shipments – Available as rolls, reels, sheets and semi-finished converted configurations.

Ideally suited as a specimen collection media for bioanalysis applications such as the collection of blood drops typical of the Guthrie test, a microbiological assay for the presence of phenylalanine, phenylpyruvate, and phenyllactate in blood or urine. Most notably the Guthrie test is used to screen newborn infants for phenylketonuria (PKU).

Dried Blood Spot Analysis

Known competitive grades*:

  • GE Healthcare Whatman / S&S 903, Ahlstrom 226

*Use of competitive trademark or nomenclature for reference only. No ownership or license rights implied.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:
High Purity Cellulose Paper

Grade
WT-2500hpc

Cotton Linter Paper

Physical Properties

Grade Nomenclature Surface Material Type Thickness
(mm)
Migration Basic weight
(g/m2)
WT-2500hpcVery Smooth
Bright White
Alpha Cotton Linter Cellulose
Paper
0.1925µm80

Ideally suited as a high resolution indicator paper and specimen collection media for bioanalysis applications such as the collection of blood drops, urine or saliva. Efficient when used as a wick or absorbent pad under membrane for lateral flow or cross flow designs.

This unique media is an ultra-high purity cellulose filter paper. The proprietary production methods employed produce a media, which demonstrates a highly durable surface texture without the high level of organic extractables common to traditional acid-hardening processes. The alpha cellulose content is a minimum of 97.5% or above and is single source.

High purity alpha cotton linter absorbent filter paper specifically formulated to yield a stable DNA, RNA and protein biomarker matrix for quantitative analysis. The formation is highly uniform and free from density irregularities allowing fast indication and strong line hold.

Uniform screen & felt sides with consistent density MD/CD - Manufacturing performed with RO water filtration system - This media demonstrates excellent lot-to-lot reproducibility - Material chemistries are verified against a standard using GC techniques prior to paper making process - CofC and CofA provided with shipments – Available as rolls, reels, sheets and semi-finished converted configurations.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:
High Purity Cellulose Paper

Grade
CFP1

Cotton Linter Paper

Physical Properties

Grade Nomenclature Surface Material Type Thickness
(mm)
Retention Basic weight
(g/m2)
CFP1Smooth
Bright White
Alpha Cotton Linter Cellulose
Paper
0.2011µm86

Ideally suited as a general sample collection pad, wicking channel in microfluidic designs and base paper in reagent saturations. High resolution indicator paper and specimen collection media for bioanalysis applications such as the collection of blood drops, urine or saliva. Efficient when used as a wick or absorbent pad under membrane for lateral flow or cross flow designs.

This general purpose media is high purity cellulose filter paper. The proprietary production methods employed produce a media, which demonstrates a highly durable surface texture without the high level of organic extractables common to traditional acid-hardening processes. The ash content of this paper is 0.05% and is always single source cotton.

High purity alpha cotton linter absorbent filter paper specifically formulated to yield a stable DNA, RNA and protein biomarker matrix for quantitative analysis. The formation is highly uniform and free from density irregularities allowing fast indication and strong line hold.

Uniform screen & felt sides with consistent density MD/CD - Manufacturing performed with DI water filtration system - This media demonstrates excellent lot-to-lot reproducibility - Material chemistries are verified against a standard using GC techniques prior to paper making process - CofC and CofA provided with shipments – Available as rolls, reels, sheets and semi-finished converted configurations.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:
High Purity Cellulose Paper

Grade
CFP2

Cotton Linter Paper

Physical Properties

Grade Nomenclature Surface Material Type Thickness
(mm)
Retention Basic weight
(g/m2)
CFP2Smooth
Bright White
Alpha Cotton Linter Cellulose
Paper
0.178µm101

15% thinner caliper than CFP1, with a 15% higher basis weight. This higher density, tighter porosity paper 61yields faster wicking rates and surface absorption. It is ideally suited as a general sample collection pad, wicking channel in microfluidic designs and base paper in reagent saturations. High resolution indicator paper and specimen collection media for bioanalysis applications such as the collection of blood drops, urine or saliva. Efficient when used as a wick or absorbent pad under membrane for lateral flow or cross flow designs.

This general purpose media is high purity cellulose filter paper. The proprietary production methods employed produce a media, which demonstrates a highly durable surface texture without the high level of organic extractables common to traditional acid-hardening processes. The ash content of this paper is 0.05% and is always single source cotton.

High purity alpha cotton linter absorbent filter paper specifically formulated to yield a stable DNA, RNA and protein biomarker matrix for quantitative analysis. The formation is highly uniform and free from density irregularities allowing fast indication and strong line hold.

Uniform screen & felt sides with consistent density MD/CD - Manufacturing performed with DI water filtration system - This media demonstrates excellent lot-to-lot reproducibility - Material chemistries are verified against a standard using GC techniques prior to paper making process - CofC and CofA provided with shipments – Available as rolls, reels, sheets and semi-finished converted configurations.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:
High Purity Cellulose Paper

Grade
CFP4

Physical Properties

Grade Nomenclature Surface Material Type Thickness
(mm)
Retention Basic weight
(g/m2)

This low density, loose porosity paper yields the fastest wicking rates and surface absorption of the grades in its class.  It is ideally suited as a general sample collection pad, wicking channel in microfluidic designs and base paper in reagent saturations.  Well defined resolution for indicator paper and specimen collection media for bioanalysis applications such as the collection of blood drops, urine or saliva. Efficient when used as a wick or absorbent pad under membrane for lateral flow or cross flow designs.

This general purpose media is high purity cellulose filter paper. The proprietary production methods employed produce a media, which demonstrates a highly durable surface texture without the high level of organic extractables common to traditional acid-hardening processes. The ash content of this paper is 0.05% and is always single source cotton.

High purity alpha cotton linter absorbent filter paper specifically formulated to yield a stable DNA, RNA and protein biomarker matrix for quantitative analysis.  The formation is highly uniform and free from density irregularities allowing fast indication and strong line hold.

Uniform screen & felt sides with consistent density MD/CD - Manufacturing performed with DI water filtration system - This media demonstrates excellent lot-to-lot reproducibility - Material chemistries are verified against a standard using GC techniques prior to paper making process - CofC and CofA provided with shipments – Available as rolls, reels, sheets and semi-finished converted configurations.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:
Highly absorbent paper, sample wick

Grade
CFP1654

Sample Wick, Absorbent

Physical Properties

Grade Nomenclature Surface Material Type Thickness
(mm)
Migration Speed Basic weight
(g/m2)
CFP1654Smooth
Bright White
Alpha Cotton Linter Cellulose
Paper
0.70135mm / 10min270

The furnish composition is of 100% high purity cotton linters with no resin or binder content. The even density and high grade formation yields a very consistent and reproducible migration in both MD and CD. Naturally hydrophilic with no additional surfactants or additives necessary to yield high performance surface absorption rates and lateral migration speeds.

The uniformity of this media affords a high liquid volume capacity with little to no leakage along strip. Material demonstrates excellent lay-flat characteristics in reel-to-reel processing. Its high purity allows for low extractables and minimal loss of analyte, therefore test resolution may be maintained even at high sample volume. The proprietary production methods employed produce a media which demonstrates a highly durable surface texture without the high level of organic extractables common to traditional acid-hardening processes. The cotton linter furnish is single source.

Ideal as an absorbent pad in diagnostic devices, base material in membrane separations, channel wicks in lateral flow configurations and high resolution visual indicative and colorimetric tests.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:
Cellulose and mixed soft wood paper with impermeable backing

WTCFP-PE1

Physical Properties

Grade Nomenclature Surface Material Type Thickness
(mm)
Migration Speed Basic weight
(g/m2)

Unique highly absorbent cellulose paper of cotton and mixed soft wood pulp furnish lined with a crystal clear polyethylene film.  Material is tear resistant with good lay-flat properties and minimal roll-memory.  Ideally suited as an absorbent pad, moisture sink, indicator strip backer base material, impermeable barrier or multi-layer pad platform.

Polyethylene is ideal for heat setting, ultrasonic welding and tack adhesion of layered stack device design.  Film is impermeable therefore liquid sample wicks on cellulose portion laterally, but does not absorb through film.  Cellulose portion is highly absorbent and demonstrates very high migration speed making this an ideal moisture sink in complex multi-layer membrane and pad designs – or a design whereby sample penetration is not desirable.

Material is manufactured from carefully selected mixed fiber which is fully oxygen bleached and resin free.  The uniformity of this media affords a high liquid volume capacity with little to no leakage along strip.  Minimal extraneous fiber or fiber shed is observed in converting and processing.

Very high tensile strength for heavy saturations and tight caliper limits for precision coatings.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:
Binderless Glass Microfiber

Grade B

Physical Properties

Grade Nomenclature Particle Retention Material Type Thickness
(mm)
Filtration Speed
(sec)
Basic weight
(g/m2)
B1.00Binderless borosilicate glass microfiber0.6530140

Rapid wetting and wicking rates make this media ideal for sample pad collection and wicking platforms.  The material is inherently hydrophilic, therefore there have been no additives introduced.  This material is free of binder which enables use in sensitive and high resolution tests.

The media is thick with a medium density allowing high resolution line formation and holding capacity.  Improved tensile strength with reliable reel-to-reel handling capacity including applications where heavy saturation or precision coatings are applied.

Fine porosity, medium to fast flow rate, with a 1.0µm size particle retention. Ideally suited for the collection of biochemical polymers that have been precipitated by denaturation. This material is twice as thick as Grade A with a higher loading capacity. May also be used as a solid particulate filter for gasses or as a prefilter.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:
Binderless Glass Microfiber

Grade C

Physical Properties

Grade Nomenclature Particle Retention Material Type Thickness
(mm)
Filtration Speed
(sec)
Basic weight
(g/m2)
C1.20Binderless borosilicate glass microfiber0.282550

Rapid wetting and absorption rates make this media ideal for sample pad collection and wicking platforms.  The material is inherently hydrophilic, therefore there have been no additives introduced.  It is free of binder which enables use in sensitive and high resolution tests.  This media demonstrates very high surface absorption properties making it ideal as a rapid liquid sample transfer pad for use under membrane in cross-flow (vertical) or equally as efficient as a wicking device in lateral flow applications.

The media is a versatile medium caliper, medium density grade which allows sufficient tensile strength for reliable reel-to-reel handling capacity.  Media shears cleanly due to a unique formation including both short and medium length fibers.  Very smooth surface with even density is ideal for precision coatings of both gravure and anilox type applications.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:
Binderless Glass Microfiber

Grade F

Physical Properties

Grade Nomenclature Particle Retention Material Type Thickness
(mm)
Filtration Speed
(sec)
Basic weight
(g/m2)
F0.70Binderless borosilicate glass microfiber0.408080

Rapid wetting and wicking rates make this media ideal for sample pad collection and wicking platforms.  The material is inherently hydrophilic, therefore there have been no additives introduced.  This material is free of binder which enables use in sensitive and high resolution tests.

The media demonstrates a very precise and even formation with little density phasing.  It is designed to tight tolerance in both caliper and density for most consistent results in lateral flow designs.  It is thin with a high density allowing high resolution line formation and holding capacity.  Short fibers allow fast transfer of sample along machine direction (MD) in lateral flow applications, while producing a very tight and closely regulate pore structure.  The very even surface is ideal for high precision gravure coatings.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:
Wicking, Absorbent, Conjugate Pad

Grade B-85

Glass microfiber

Physical Properties

Grade Nomenclature Particle Retention Material Type Thickness
(mm)
Filtration Speed
(sec)
Basic weight
(g/m2)
B-851.00Binderless borosilicate glass microfiber0.434764

Rapid wetting and wicking rates make this media ideal for sample pad collection and wicking platforms.  The material is inherently hydrophilic, therefore there have been no additives introduced.  This material is free of binder which enables use in sensitive and high resolution tests.

The media is thin with a high density allowing high resolution line formation and holding capacity.  Medium to long glass microfibers increase tensile strength for general dip saturation applications as well as high precision gravure coatings.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:
Wicking, Base absorbent pad, Air/Gas

Grade RG

Laminated glass microfiber

Physical Properties

Grade Nomenclature Particle Retention Material Type Thickness
(mm)
Filtration Speed
(sec)
Basic weight
(g/m2)
RG1-2Laminated
Borosilicate Glass Microfiber
0.387588.1

Rapid wetting and wicking rates make this media ideal for sample pad collection and wicking platforms. This material is a standard borosilicate glass microfiber with acrylic binder in <3% total material composition. The media is bound to a polyester scrim for support and added strength for high speed reel-to-reel processing. The support layer makes this media ideal for heavily saturated dip processing, as well as dry flat properties to be used as an absorbent layer base component.

This laminated glass product is a high efficiency multi-purpose filter medium with good heat resistance. Demonstrating a retention rate of 1-2µm, it is particularly recommended for both gas and liquid filtration in the medical field and for monitoring applications.

The supporting scrim is a 0.5 oz/yd2 Reemay, a high strength spun bonded polyester nonwoven. Also, the scrim is bonded to the glass media using a polyester hot melt which has a melting point of 325° F making it ideal for heat press, ultrasonic and heat-welded device fabrication.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:
Wicking, filtration, pre-filtration

Grade PP1

Polypropylene Media

Physical Properties

Grade Nomenclature Particle Retention Material Type Thickness
(mm)
Filtration Speed
(sec)
Basic weight
(g/m2)
PP11.0 – 1.25Polypropylene melt blown fiber0.682070

This media is a 100% high purity polypropylene melt blown fibrous depth filter. The fiber structure is very consistent and uniform in formation allowing even wicking and lateral migration. When used as a filtration media, it demonstrates very high flow rates with little back pressure, high loading capacities and has a Frazier air permeability >35ft3/min.

The media is an excellent choice for microporous membrane prefiltration applications. The PP fibers are ideal for structured devices as they bond, heat stake, ultrasonically weld and mechanically lock to other thermoplastics. The material has excellent thermal stability to 166°C. The material demonstrates minimal discoloration and negligible degradation post gamma sterilization (15kGy min - 30kGy).

Adhesive bonding is very difficult due to the chemical resistance of PP, but with a sufficiently viscous bonding solution it is possible by mechanically locking into the depth of the matrix. The material demonstrates a high tensile capacity and strong resistance to shear delamination.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <

MATERIAL CLASS:
Wicking, Base absorbent pad, Air/Gas

Grade LL-72

Laminated glass microfiber

Physical Properties

Grade Nomenclature Particle Retention Material Type Thickness
(mm)
Filtration Speed
(sec)
Basic weight
(g/m2)
LL-721-2Double Laminated
Borosilicate Glass Microfiber
0.4373115.9

Rapid wetting and wicking rates make this media ideal for sample pad collection and wicking platforms. This material is a standard borosilicate glass microfiber with acrylic binder in <3% total material composition. The media is bound on both sides to polyester scrim for support and added strength for high speed reel-to-reel processing. The double support layer makes this media ideal for very heavily saturated dip processing, as well as dry flat properties to be used as an absorbent layer base component.

This double sided laminated glass product is a high efficiency multi-purpose filter medium with good heat resistance. Demonstrating a retention rate of 1-2µm, it is particularly recommended for both gas and liquid filtration in the medical field and for monitoring applications.

The supporting scrim is a 0.5 oz/yd2 Reemay, a high strength spun bonded polyester nonwoven. Also, the scrim is bonded to the glass media using a polyester hot melt which has a melting point of 325° F making it ideal for heat press, ultrasonic and heat-welded device fabrication.

Row filter-holdings-swoopty Shape Decorative svg added to bottom <
OEM and Custom Manufacturing

Diagnostics OEM Capabilities

In addition to I.W. Tremont's significant standard production of analytical, laboratory and diagnostic products, we offer our services as your manufacturing partner.

By utilizing a wide array of disciplines and resources we can modify an existing design or completely develop a new product or process. Cost efficiency is created with tight controls in timeline, budget, concurrent processes and production scale. We efficiently develop a viable early stage engineering plan to bring the project to your desired level of completion including short run, scale up and full commercialization.

Core capabilities:

• Wet lay processes for glass microfiber and cellulose media development
• Porous media development including modification of standard grades
• Hundreds of standard material grades in glass, cellulose and synthetics
• Converting such as slitting, die cutting, shearing, laminating & interleaving
• Component design for injection molding
• Component assembly using ultrasonic welding
• Inspection, insertion and encapsulation
• Device optimization and process consulting
• Short run to mid-volume manual operations
• Custom syringe and inline filter devices with integrity testing
• Kitting and special packaging
• ISO Class 8 & 9 clean room assembly and production

Partnered capabilities:

• Paper chemistry and pilot production
• Lateral flow device design and development
• Point of care device design
• Test strip production
• Micro gravure coating
• Rapid whole blood separation technologies
• Microfluidic device design

OEM Capabilities
Row filter-holdings-swoopty Shape Decorative svg added to bottom <
I.W. Tremont

Find the Right Technical Paper for Your Application

Since 1979, I.W. Tremont has produced high-quality filtration and specialty media for laboratories, diagnostics, and technical applications—combining material science expertise with exceptional service.